"How far apart should the poles be?" is the first question on almost every street lighting project, and the honest answer is: it depends on the road, the luminaire and the light level you need. This guide walks through the decisions in the order a lighting designer makes them, so you can check a design, compare offers or brief a supplier.
Step 1: choose the lighting class
Most international and many national specifications use the European standard EN 13201 (and the CIE 115 recommendation it is based on). It sorts lit areas into three families:
- M classes (M1 to M6) for motorised traffic roads, measured as road surface luminance in cd/m².
- C classes (C0 to C5) for conflict areas such as junctions, roundabouts and shopping streets, measured as illuminance in lux.
- P classes (P1 to P6) for pedestrian areas, footpaths, cycle tracks and residential streets, also in lux.
| Class | Average luminance (cd/m²) | Overall uniformity Uo | Typical use |
|---|---|---|---|
| M1 | 2.0 | 0.40 | Motorways, high-speed main roads |
| M2 | 1.5 | 0.40 | Main roads with heavy traffic |
| M3 | 1.0 | 0.40 | Main urban roads |
| M4 | 0.75 | 0.40 | Secondary roads |
| M5 | 0.50 | 0.35 | Local distributor roads |
| M6 | 0.30 | 0.35 | Minor roads |
The class is chosen from the speed, traffic volume, mix of users, junction density and ambient brightness. Many cities and utilities publish their own class tables; when they exist, they take priority.
Step 2: choose the pole arrangement
| Arrangement | When it is used |
|---|---|
| Single-sided | Narrow roads, roughly where the road width is up to the mounting height |
| Staggered | Medium widths, roughly 1 to 1.5 times the mounting height |
| Opposite | Wide roads, above about 1.5 times the mounting height |
| Central (twin-arm on the median) | Dual carriageways with a central reservation |
These ratios are starting points. The final choice also depends on trees, existing poles, cable routes and the budget for civil works.
Step 3: mounting height
Higher poles spread light further and allow wider spacing, but need more powerful luminaires, stronger foundations and more expensive maintenance equipment. Typical heights are 6 to 8 m for residential streets, 8 to 10 m for urban roads and 10 to 12 m or more for main roads and highways. Use the same height along a road so the uniformity calculation holds.
Step 4: spacing comes from the calculation
A common first estimate is a spacing of about three to four times the mounting height. A 10 m pole would suggest 30 to 40 m. Treat this only as a starting point: the real spacing is the largest one at which the design still meets the class's average level and its uniformity. Uniformity is usually what limits spacing, not the average.
The calculation is made in software such as DIALux or Relux, using the luminaire's photometric file (IES or LDT/EULUMDAT), the road width, the number of lanes, the pole height, the arm length and tilt, the road surface and a maintenance factor.
A worked example
For a first check on an illuminance-based class, the lumen method gives the average level on the road:
E = (Φ × UF × MF) ÷ (S × W)
where Φ is the luminaire's flux in lumens, UF the utilisation factor (the share of the light that lands on the road), MF the maintenance factor, S the spacing and W the road width.
Take a 150 W Pacific luminaire with 17,255 lm, a 10 m wide road, a 35 m spacing, a utilisation factor of 0.45 and a maintenance factor of 0.8:
E = (17,255 × 0.45 × 0.8) ÷ (35 × 10) ≈ 17.7 lux average
The utilisation factor in this example is an assumption; the real figure comes from the luminaire's photometric file and the geometry. The lumen method also says nothing about uniformity or glare. Use it to check whether an offer is in the right range, then confirm the design with a full calculation.
Step 5: the maintenance factor
A new installation gives more light than it will after a few years. The maintenance factor accounts for the fall in LED output over time and for dirt on the optic. Values around 0.8 are common for sealed IP65 LED luminaires in clean areas; dusty or polluted areas need a lower figure. A design calculated with a maintenance factor of 1.0 will be under-lit later in its life.
What to send a supplier
- Road width, number of lanes, and the width of footpaths and medians
- Required lighting class, or the speed and traffic so the class can be proposed
- Pole height, arm length and existing pole positions, if poles are reused
- Arrangement (single-sided, staggered, opposite, central)
- Supply voltage and whether dimming or a control system is needed
- Site conditions: dust, coastal air, wind
Our LED street light buyer's guide covers the luminaire itself: efficacy, optics, surge protection and documents.
Street lighting from SEGA M
SEGA M designs and manufactures LED street lights in Egypt. The Pacific (105 W with 13,260 lm, 150 W with 17,255 lm) is our heavy-duty model for highways and main roads, and the Rocky (105 W and 150 W, with lens or lens-free optics) serves main roads and urban streets. Both are IP65 and IK08, in 3000 K, 4000 K and 6000 K.
Our laboratory is accredited by EGAC to ISO/IEC 17025 for light measurement and measures every model on a goniophotometer. Send us your road layout and we will run the lighting calculation and propose the luminaire and spacing.
Frequently asked questions
What is the standard spacing for street light poles?
There is no single standard spacing. A first estimate is three to four times the mounting height, but the final spacing comes from a lighting calculation that meets the road's class for both average level and uniformity.
What is the difference between M, C and P lighting classes?
M classes are for traffic roads and are measured as luminance. C classes are for conflict areas such as junctions, and P classes for pedestrian areas; both are measured as illuminance in lux.
How high should a street light pole be?
Typically 6 to 8 m for residential streets, 8 to 10 m for urban roads and 10 to 12 m or more for main roads and highways.
Can SEGA M do the lighting calculation for our road?