Siemens Technology Partner LV0620-007
SIVACON S8 switchboards, built by SEGA M
Type-tested low-voltage switchboards for main distribution, sub-distribution and motor control, built to the Siemens design in our factory in Egypt and approved by the Egyptian Electricity Holding Company.
Approved for your tender
- Siemens Technology PartnerCertificate LV0620-007, valid to 12.08.2027
- EEHC approvalSIVACON S8 switchboards up to 3,600 A, valid to 26.04.2029
- International approvalsCE, EAC, CCC and DNV GL approved
- Type testedIEC 61439-2, internal arc to IEC/TR 61641
One system for every feeder
Mix cubicle types in one line-up, with single-front or double-front layout and cable entry from top or bottom.
Circuit-breaker design
Incomers, couplers and outgoing feeders with air circuit-breakers up to 6,300 A.
Universal design
Plug-in and withdrawable cable feeders up to 630 A and motor feeders up to 250 kW.
Fixed-mounted design
Fixed-mounted cable feeders for simple and economical distribution.
In-line design
In-line switch-disconnectors for compact cable feeders.
Reactive power compensation
Power factor correction cubicles up to 600 kvar.




Technical data
| Standard | IEC 61439-2 / EN 61439-2 / VDE 0660-600-2 |
|---|---|
| Internal arc test | IEC/TR 61641 |
| Rated operating voltage (Ue) | up to 690 V, 50 Hz |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Rated insulation voltage (Ui) | 1,000 V |
| Main busbar rated current | up to 7,010 A |
| Rated peak withstand current (Ipk) | up to 330 kA |
| Rated short-time withstand current (Icw) | up to 150 kA, 1 s |
| Circuit-breaker rated current | up to 6,300 A |
| Cable and motor feeders | up to 630 A, motors up to 250 kW |
| Internal separation | Form 1 to Form 4 (IEC), up to Form 4 type 7 (BS EN) |
| Degree of protection | IP30 to IP43 ventilated, IP54 non-ventilated |
| Mechanical strength | IK10 (IEC 62262) |
| Frame height | 2,000 or 2,200 mm, base 100 or 200 mm |
| Cubicle widths | 200 – 1,400 mm |
| Depths | 500 – 1,200 mm |
Switchboards from our factory power these projects
A selection of SEGA M low-voltage switchboard projects, Frame 2 (2,500 to 3,200 A) and Frame 3 (4,000 to 6,300 A).
- Ain Shams University Obour Hospital
- Ain Shams University Eldemerdash Hospital
- New Saudi Embassy Chancellery, Cairo
- WEPCO WAQ platform, oil and gas
- Egyptian Railways stations renewal
- Nile Badrawy Hospital
- Pyramid Plateau Project
- Monopharma factory, Badr City
- Venus ceramic factory
- Badr University
- Samanoud Hospital
- The Liver Institute
From drawing to delivery
Send your drawings
Single-line diagram, BOQ or specification. A short description of the load is enough to start.
Receive the offer
Our export team replies within 24 hours and prepares the technical and commercial offer.
Approve the drawings
We send the layout drawings for your approval before production starts.
Build and routine test
Every board is built in our factory and routine tested before it leaves.
Ship
Lead time from stock items ready at once to about 6 weeks for larger projects.
Questions buyers ask us
Is a SEGA M SIVACON S8 the same as one built by Siemens?
SEGA M builds SIVACON S8 under a Siemens Technology Partner agreement (LV0620-007) that gives us the right to manufacture and sell the design-verified SIVACON switchboard, with Siemens switching devices.
Up to which current can you build?
Main busbars up to 7,010 A and circuit-breakers up to 6,300 A. Our EEHC approval covers SIVACON S8 switchboards up to 3,600 A.
Which IP degree can you offer?
IP30 to IP43 for ventilated switchboards and IP54 for non-ventilated switchboards.
What do you need for a quotation?
The single-line diagram, the short-circuit level, the IP degree and the form of separation. Our engineers fill any gaps with you.

Send us your single-line diagram. We reply within 24 hours.
Tell us the project, the ratings and the destination country. Our export team prepares the offer and the drawings.