Classification, dimensions, room planning
SKU:
N/A
Category: Low Voltage Distribution Board
Shipping & Delivery
Related products
Cable Compartment
-
Cable Compartment
-
Standard
-
Cable entry from bottom, earth bar and bushings to the switching device compartment
-
Variations
-
Cable fault making earth switch (25kA/1s) Current Transformer
-
Block Type
-
Voltage Transformer, Block type Cable connections up to 4 cable / phase Lightning arrestor
-
Gland plate
-
Steel, Aluminium, Stainless Steel, Brass Cable entry
-
Top, adds additional 600 mm cable box
Select options
This product has multiple variants. The options may be chosen on the product page
CABLE GLAND Copy
Cable gland IP 65 with stress relief metric threaded connection. Fiber glass polymide Impact & temperature resistant Grey RAL 7035 Available in different Dimensions
Select options
This product has multiple variants. The options may be chosen on the product page
Classification, dimensions, room planning
-
Single-row arrangement (plan view) For dimensions B (width) and T (depth) refer to table on this page
-
For panel replacement: Control aisle 2000 mm
-
Minimum distance to wall 150 mm
Select options
This product has multiple variants. The options may be chosen on the product page
Lamina1 100W
LED Street Lighting Luminaire for Urban and Suburban communities
Versatile, modular and highly adaptable
Suitable for both new installations and retrofitting
60-105W
100 Lm/W
IP65
Select options
This product has multiple variants. The options may be chosen on the product page
Medium Voltage -Switchgear, 12 kV up to 17.5 kV Type
-
Saves Lives
-
All switching operations including emergency manual operation switch high-voltage door closed
-
Internal arc tested design up to 40 kA, 1 s, according to IEC 62271-200, VDE 0671-200
-
Peace Of Mind
-
Design based on global best practice sharing and experience
-
Type testing of the circuit-breaker inside the panel
-
Factory-assembled, type-tested switchgear according to IEC 62271-200
-
Use of maintenance-free vacuum circuit-breakers
-
Increases Productivity
-
Use of metallic, earthed shutters and partitions between the compartments ensures highest loss of service continuity of the switchgear (LSC2B according to IEC 62271-200) during maintenance
-
Use of maintenance-free vacuum circuit-breakers
-
Saves Money
-
Use of maintenance-free vacuum circuit-breakers
Select options
This product has multiple variants. The options may be chosen on the product page
Metal-clad, withdrawable
-
Selective disconnection by Block type current transformers
-
Truck Type Vacuum Circuit Breaker
-
Economic functional design
-
Compact dimensions (800 mm width)
-
Individually operated shutters
-
Fully mechanically interlocked
-
All switching operations behind closed HV Door
-
Separate LV Compartment
-
Primary fused withdrawable PT
-
Top Cable Entry (option)
-
Suitable for trench mounting
Select options
This product has multiple variants. The options may be chosen on the product page
Panel Design
-
(Panel design)
-
Door of low-voltage
-
compartment
-
Opening for locking or un locking
-
the low-voltage
-
compartment door
-
Option: Capacitive voltage
-
detecting systemfor feeder
-
and busbar
-
High-voltage door
-
Inspection window for
-
checking the switchingdevice
-
truck
Select options
This product has multiple variants. The options may be chosen on the product page
SIVACON-S8
System Overview
The interaction of the components described below results in an optimal low-voltage switchboard with advantages as regards:
- Safety - integrated
- Economic efficiency- right from the start
- Flexibility – through modularity
Select options