SIVACON-S8
System Overview
The interaction of the components described below results in an optimal low-voltage switchboard with advantages as regards:
– Safety – integrated
– Economic efficiency- right from the start
– Flexibility – through modularity
SKU:
N/A
Category: Low Voltage Distribution Board
Description
SIVACON-S8
Technical data, standards and approvals for the SIVACON S8 switchboard
Low Voltage Distribution Board
SIVACON-S8
Cubicle Design of SIVACON S8
Low Voltage Distribution Board
SIVACON-S8
System Conἀguration and Cubicle Design
Low Voltage Distribution Board
SIVACON-S8
Schematic Overview of Switchboard Conἀgurations for SIVACON S8
Low Voltage Distribution Board
These characteristics depend on the type of installation among other things:
• Stand-alone• At the wall (only for single-front design)
• Back to back (only for single-front design)
These determinations allow to specify cubicle design in more detail (Fig. 2/1, Tab. 2/2 and Tab. 2/3). Further infor-mation about the switchboard installation can be found in Chapter 8 “Further planning notes”.
SIVACON-S8
Cubicle Types and Busbar Arrangement
Low Voltage Distribution Board
SIVACON-S8
Cubicle Dimensions
Low Voltage Distribution Board
The cubicle dimensions listed in Tab. 2/4 do not factor in the enclosure parts and no outer built-on parts.
For the dimensions of the cubicles’ enclosure parts, please refer to Fig. 2/2. For degrees of protection IPX1 and IPX3, additional ventilation roof panels are mounted on the cubicle.
The dimensions of the enclosure parts are within the required minimum clearances for erecting the switchboard. Doors can be fitted so that they close in escape direction.
The door stop can easily be changed later. The door hinges allow for a door opening angle of up to 180° in case of single installation of a cubicle and at least 125° when cubicles are lined up. For more details, please refer to Chapter 8 “Further planning notes”. The condition of sur-faces of structural and enclosure parts is described in Tab. 2/5.
SIVACON-S8
Surface Treatment
Low Voltage Distribution Board
Shipping & Delivery
Related products
Cable Compartment
-
Cable Compartment
-
Standard
-
Cable entry from bottom, earth bar and bushings to the switching device compartment
-
Variations
-
Cable fault making earth switch (25kA/1s) Current Transformer
-
Block Type
-
Voltage Transformer, Block type Cable connections up to 4 cable / phase Lightning arrestor
-
Gland plate
-
Steel, Aluminium, Stainless Steel, Brass Cable entry
-
Top, adds additional 600 mm cable box
Select options
This product has multiple variants. The options may be chosen on the product page
CABLE GLAND Copy
Cable gland IP 65 with stress relief metric threaded connection. Fiber glass polymide Impact & temperature resistant Grey RAL 7035 Available in different Dimensions
Select options
This product has multiple variants. The options may be chosen on the product page
Circuit Breaker Compartment Type-tested
-
Standard
-
Withdrawable Vacuum Circuit breaker type 3AH equipped with: Tripping Coil, Closing Coil, and Spring Charging Motor. Variations
-
for Circuit Breaker options
-
Range of Operating Voltages
-
Second Trip Coil
-
Undervoltage Release
-
Electrical Lockout
-
Extended Auxiliary Switches
Select options
This product has multiple variants. The options may be chosen on the product page
Classification, dimensions, room planning
-
Single-row arrangement (plan view) For dimensions B (width) and T (depth) refer to table on this page
-
For panel replacement: Control aisle 2000 mm
-
Minimum distance to wall 150 mm
Select options
This product has multiple variants. The options may be chosen on the product page
JUNCTION BOX
Connection Boxes in insulating material in a good design shape. protection degree complying with IEC 529 IP 44 & 54 & 67 Grey Ral 7035 High impact material : I
K8 mechanical protection degree according to CEI EN 5010 standard flame and fi
re resistance according to IEC 695-2- Halogen free. Total insulation features (CEL 64-8, EN 60439-1CEL 17-13/1) (IEC 60309-1) Temperature rating :- 25c to + 80c screw close cover Screw close cover Glow-wire test:IEC 598-1,Section (13,13.3.2) cable gland pg :16 & 29 Sizes in mm
Select options
This product has multiple variants. The options may be chosen on the product page
Lamina2 100W
LED Street Lighting Luminaire for Urban and Suburban communities
Versatile, modular and highly adaptable
Suitable for both new installations and retrofitting
60-105W
100 Lm/W
IP65
Select options
This product has multiple variants. The options may be chosen on the product page
Legend for panel design
-
Legend for panel design
-
Door of low-voltage
-
compartment
-
Opening for locking or unlocking
-
the low-voltage
-
compartment door
-
Option: Capacitive voltage
-
detecting system for feeder
-
and busbar
-
High-voltage door
-
Inspection window for
-
checking the switchingdevice
-
truck
Select options
This product has multiple variants. The options may be chosen on the product page
MCCB DISTRIBUTION
MCCB DISTRIBUTION BOARD
-
Incoming 3va23-3vm13-400A, Outgoing 3va1-3vm1 16-160A
-
Incoming 3va22-3vm12-250A, Outgoing 3va1-3vm1 16-160A
-
Perfect Design
-
Very Good Quality
-
Total Safety
-
Time Saving
Select options
This product has multiple variants. The options may be chosen on the product page









